Stitex Technologies

Monitoring · ventilation, heat substations, cooling, panels

Monitoring and control system for engineering equipment

Equipment status, faults and an operating log in one window. You hear about a fault from the system, not from a tenant. Settings change remotely.

Price after a site survey

system types: ventilation, heat substations, cooling, panels
4
fault alert to the right person
at once
the site keeps running
offline
a demo on your own task
on request

What the customer sees

One screen instead of walking round the panels. Access rights are set per site.

What the customer sees
SectionWhat is in it
StatusCurrent parameters and modes of each unit: what is on, what the temperature is, where it deviates from the setpoint.
FaultsA message at once and to a named person: what happened, where and when. The alert reaches whoever is responsible, not a shared mailbox.
LogHistory of parameters and faults for each unit. It lets you review an incident afterwards, and the history can be exported to your own format.
ControlRemote change of setpoints and modes of the equipment.

Equipment we cover

We work with automation already installed, from different manufacturers; new panels are not required for monitoring.

Equipment we cover
SystemWhat becomes visible
Ventilation and heat recoveryUnit operating mode, temperatures, state of the units, faults.
Heat substations and thermal unitsCircuit temperatures, pump state, faults, history — it shows a fault developing before the stop.
Cooling: chillers, condensing unitsCircuit operating parameters, faults, history of deviations.
Control panelsPanel signals and faults instead of a lamp on the door that nobody sees.

How we set it up

We start with one important unit and verify the whole chain from sensor to the message to the duty person. Then we extend to the other systems.

How we set it up
StepWhat we do
1. SurveyWe see which units and controllers are installed and what they can report→ a list of monitoring points
2. Faults and recipientsTogether we define what counts as a fault and who is told→ an alert procedure
3. Pilot on one unitWe bring the most important unit online and verify the whole chain→ a working system on one unit
4. Link and autonomyWe choose the communication channel and test behaviour when it drops→ no data lost, history catches up once the link returns
5. ExtensionWe add the remaining building systems or other sites→ one picture across sites

Lead times

Indicative; the exact term is stated after the survey.

Lead times
TaskTime
One site: survey, setup, alert configuration, staff trainingabout 2 weeks
Fault monitoring on existing equipmentabout 1 week
A network of several sites: one map, rights per site, summary reportsfrom 5 weeks

What we need from the site

What we need from the site
WhatWhy
Access to the site for the surveyto see the units, panels and controllers first-hand
A list of equipment and schematics, if they existto see where linking to existing automation is enough
The faults that must not be missed and who owns themto set up addressed alerts
A communication channel on site: internet or mobile networkto send status and receive commands
One responsible person on the customer sideto agree access, rights and procedure

Limits of the system

Limits of the system
PrincipleWhat it means
Protections stay on siteInterlocks and safety protections run in the panel. The top level does not control them: if the link drops, the equipment keeps running on its own automation.
It does not replace servicingIt reports a fault and keeps the history. Repair and servicing of equipment is separate work.
The history is yoursData can be exported, so reviewing an incident does not depend on us.

Price

Calculated per site after the survey: it depends on the number of monitoring points, the equipment type and the communication channel. We state the price and scope before work starts.

Request a quote

Demo on request

We show the system on a task close to yours: how status, faults and the log look. Leave a request and we will agree a time.

Demo on request

Contact

Tell us about the site

Write what equipment is installed and what you want to see. We reply with a survey plan and lead times.

Telegram
@StitexBot
Response time
Within 1–2 business hours

B2B & Commercial:

  • All prices include 22% VAT
  • Electronic tax invoices & formal agreement
  • 3-month warranty on completed code